B-9689-1000

Temperature Rating, Non-UL: -30ºC To +75ºC
Capacitance: 2.625^1.000
Capacitance (Metric): 2.625^1.000
Current, Max. Recommended: 2.3 Amps per conductor @ 25ºC
Impedance: 150^600^105
Voltage, Max. Operating: 300 V RMS
Velocity of Propagation: 66^78
SKU: B-9689-1000
Manufacturer: Belden
CEC/C(UL) Specification: CMG
NEC/(UL) Specification: CMG
Mfr. Part No: 9689 0101000
Flame Test - UL Flame Test: UL1685 FT4 Loading
Weight: 0.0800
Color: BLACK
Cable Type: Paired
Conductor Size (AWG): 22
Conductor Material: BC - Bare Copper
Number of Conductors: 12
Number of Pairs: 6
Conductor Stranding: Solid
Insulation Material: FRFPE - Flame Retardant Foam Polyethylene^ FRPE - Flame Retardant Polyethylene
Overall Nominal Diameter: .324 x .466
Outer Jacket Material: PVC - Polyvinyl Chloride
Outer Shield Material: Polyester Tape
Outer Shield Type: Tape
Amount: 1000 ft
Overall Cabling - Overall Nominal Diameter (Metric): 8.2296 x 11.8364
Belden 9689 0101000 - 22 AWG - 12 C - 1000 FT - 300 V RMS - BLACK (B-9689-1000) DatasheetAdd to Compare

B-82689-1000

Temperature Rating, Non-UL: 0ºC To +75ºC
Capacitance: 1.00^2.625
Capacitance (Metric): 1.00^2.625
Current, Max. Recommended: 2.3 Amps per conductor @ 25ºC
Impedance: 150^600^105
Voltage, Max. Operating: 300 V RMS
Velocity of Propagation: 66^78
SKU: B-82689-1000
Manufacturer: Belden
CEC/C(UL) Specification: CMP
RoHS: Yes
EU CE Mark: Yes
NEC/(UL) Specification: CMP
Mfr. Part No: 82689 0101000
Plenum: Yes
Flame Test - UL Flame Test: NFPA 262
Weight: 0.0800
Color: BLACK
Cable Type: Paired
Conductor Size (AWG): 22
Conductor Material: BC - Bare Copper
Number of Conductors: 12
Number of Pairs: 6
Conductor Stranding: Solid
Insulation Material: FFEP - Foam Fluorinated Ethylene Propylene^ FEP - Fluorinated Ethylene Propylene
Overall Nominal Diameter: .324 x .460
Outer Jacket Material: LS PVC - Low Smoke Polyvinyl Chloride
Outer Shield Material: Polyester Tape
Outer Shield Type: Tape
Amount: 1000 ft
Overall Cabling - Overall Nominal Diameter (Metric): 8.2296 x 11.684
Belden 82689 0101000 - 22 AWG - 12 C - 1000 FT - 300 V RMS - BLACK (B-82689-1000) DatasheetAdd to Compare

* Required Fields

$0.0000
 

Quick Overview

IEEE 802.5; ISO/IEC 8802.5
SKUConductor Size (AWG)Number of PairsAmountPlenum
B-9689-10002261000 ftNo
B-82689-10002261000 ftYes
Bare Copper Conductors. Black Jacket.

Specifications

SKU IBM Type 2A Cabling System
Manufacturer Belden