Shielded Multi-Conductor
We offer a range of Multi-Conductor Shielded Cables in an assortment of different gage sizes, dimensions, insulation, jacketing and shielding materials to ensure we meet the technical requirements of our customers. 2 Conducted Shielded Cables basically mean the cable has a cover to protect from signal interference. Multi-Conductor Sheilded cables are also known as twisted pair cables.
Materials for Multi-Conductor Shielded Cable:
- Tinned copper braid
- Spiral copper tape
- Beldfoil
- Aluminum foil-polyester tape
- Silver-plated copper
- Silver-plated copper braid shields
Applications of 2 Conductor Shielded Cables:
Our range of shielded multi-conductor cables are ideal for a number of different industrial applications such as:
- Computers
- Communications
- Instrumentation
- Audio
- Control & data transfer
- Fire & security alarms
Contact us to learn more about Multi-Conductor Shielded Cables.
Items 1 to 100 of 175 total
- 1
- 2
-
Alpha Wire Communication and Control Cable, Braid Shield, Rubber
Tinned Copper Conductors. EPDM Rubber Insulation. Polychloroprene Jacket.
-
Alpha Wire Communication and Control, Multiconductor, Overall Foil/Braid
Tinned Copper Conductors. S-R PVC Insulation. PVC Jacket.
-
Alpha Wire Communication, Control and Industrial Cable, Foil Shield
300V Foil Shield, Multiconductor Communication and Control Cable.
-
Alpha Wire Communication, Control and Industrial Cable, Multiconductor
Bare Copper Conductors. Plenum-Rated PVC Insulation and Jacket.
-
Alpha Wire Communication, Control Cable, Multicond, Braid Shield, 600V
Tinned Copper. PTFE Insulation. Braid Shield. PTFE Tape Jacket
-
Alpha Wire Xtra-Guard® 1, Foil Shield, 300V
Tinned Copper Conductors. PVC Insulation. PVC Jacket.
-
Alpha Wire Xtra-Guard® 1, Supra-Shield® Foil/Braid, 300V
Tinned Copper Conductors. PVC Insulation. PVC Jacket.
-
Alpha Wire Xtra-Guard® 1, Supra-Shield® Foil/Braid, 600V
Tinned Copper Conductors. PVC Insulation. PVC Jacket.
-
Alpha Wire Xtra-Guard® 3, Direct Burial, Foil Shield, 300 V
Tinned Copper Conductors. PVC Insulation. PE Jacket.
-
Alpha Wire Xtra-Guard® 4, Advanced Temp. and Chemical Performance, Foil
Tinned Copper Conductors. TPE Insulation. TPE Jacket. (Blk Std, 9 colors avail.).
-
Alpha Wire Xtra-Guard® 4, Advanced Temp. and Chemical Performance, 300V
Tinned Copper Conductors. TPE Insulation. TPE Jacket. (Blk Std, 9 colors avail.).
-
Alpha Wire Xtra-Guard® Continuous Flex, Foil/Spiral Shield, 300V
Tinned Copper. Lubricated S-R PVC Insulation. Oil-Resistant PVC Jacket.
-
Belden 1000V Flexible Motor Supply Cable, 3 Conductor
Tinned Copper. XLPE Insulation. Shielded. 90°C Wet/Dry. 1000V.
-
Belden 1000V Flexible Motor Supply Cable, 4 Conductor
Tinned Copper. XLPE Insulation. Shielded. 90°C Wet/Dry. 1000V.
-
Belden 1348A 0021000 - 20 AWG - 3 C - 1000 EA - 300 V RMS - RED
MITSUBISHI CC LINK SIGNAL CABLE - 3 CONDUCTOR 20 AWG (7X28) BARE COPPER. FOAMED PE INSULATION. OVERALL BELDFOIL SHIELD WITH A 22 AWG (19X34) TINNED COPPER DRAIN WIRE. 78% TINNED COPPER BRAID. PVC INNER JACKET.1000 ea, RED- Mfr's Part No.: 1348A 0021000
- IWC Item No.: B-1348A-1000
-
Belden 1349A 0021000 - 18^20 AWG - 2^3 C - 1000 EA - 300 V RMS^300 V RMS - RED
MITSUBISHI CC LINK SIGNAL & POWER CABLE - 3 CONDUCTOR 20 AWG (7X28) BARE COPPER. FOAMED PE INSULATION. OVERALL BELDFOIL SHIELD WITH A 22 AWG (19X34) TINNED COPPER DRAIN WIRE. 78% TINNED COPPER BRAID. PVC INNER JACKET. TWO CONDUCTORS 18 AWG (7X26) BARE COP1000 ea, RED- Mfr's Part No.: 1349A 0021000
- IWC Item No.: B-1349A-2-1000
-
Belden 1526A 01010000 - 20 AWG - 3 C - 10000 FT - 300 V RMS - BLACK
20 AWG (7X#28) Bare COPPER. PVC INSULATION. BELDFOIL(R) 100%. 22 AWG (7X#30) TINNED COPPER DRAIN WIRE. PVC JACKET WITH NYLON RIPCORD.10000 ft, BLACK- Mfr's Part No.: 1526A 01010000
- IWC Item No.: B-1526A-10000
-
Belden 1540A 0081000 - 28 AWG - 7 C - 1000 FT - 150 V RMS - GRAY
28 AWG (7x36) Bare copper. multiconductor cable. 7 conductors step insulated with solid PP and solid PE. overall Beldfoil shield with 28 AWG (7x36) tinned copper drain wire. tinned copper braid. PVC jacket.1000 ft, GRAY- Mfr's Part No.: 1540A 0081000
- IWC Item No.: B-1540A-1000
-
Belden 2000V-UL-Flexible-Motor-Supply-Cable
Tinned Copper Conductors. XLPE Insulation. 90°C Wet/Dry. 2000V.
-
Belden 29501 010100 - 14 AWG - 3 C - 100 EA - 1000 V RMS - BLACK
14 AWG (41x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 14 AWG (41x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.100 ea, BLACK- Mfr's Part No.: 29501 010100
- IWC Item No.: B-29501-100
-
Belden 29501 0101000 - 14 AWG - 3 C - 1000 FT - 1000 V RMS - BLACK
14 AWG (41x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 14 AWG (41x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.1000 ft, BLACK- Mfr's Part No.: 29501 0101000
- IWC Item No.: B-29501-1000
-
Belden 29501 010250 - 14 AWG - 3 C - 250 FT - 1000 V RMS - BLACK
14 AWG (41x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 14 AWG (41x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.250 ft, BLACK- Mfr's Part No.: 29501 010250
- IWC Item No.: B-29501-250
-
Belden 29501 010500 - 14 AWG - 3 C - 500 FT - 1000 V RMS - BLACK
14 AWG (41x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 14 AWG (41x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.500 ft, BLACK- Mfr's Part No.: 29501 010500
- IWC Item No.: B-29501-500
-
Belden 29501 0105000 - 14 AWG - 3 C - 5000 FT - 1000 V RMS - BLACK
14 AWG (41x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 14 AWG (41x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.5000 ft, BLACK- Mfr's Part No.: 29501 0105000
- IWC Item No.: B-29501-5000
-
Belden 29502 010100 - 12 AWG - 3 C - 100 EA - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
12 AWG (65x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.100 ea, BLACK- Mfr's Part No.: 29502 010100
- IWC Item No.: B-29502-100
-
Belden 29502 0101000 - 12 AWG - 3 C - 1000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
12 AWG (65x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.1000 ft, BLACK- Mfr's Part No.: 29502 0101000
- IWC Item No.: B-29502-1000
-
Belden 29502 010250 - 12 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
12 AWG (65x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.250 ft, BLACK- Mfr's Part No.: 29502 010250
- IWC Item No.: B-29502-250
-
Belden 29502 010500 - 12 AWG - 3 C - 500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
12 AWG (65x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.500 ft, BLACK- Mfr's Part No.: 29502 010500
- IWC Item No.: B-29502-500
-
Belden 29502 0105000 - 12 AWG - 3 C - 5000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
12 AWG (65x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.5000 ft, BLACK- Mfr's Part No.: 29502 0105000
- IWC Item No.: B-29502-5000
-
Belden 29503 010100 - 10 AWG - 3 C - 100 EA - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
10 AWG (105x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor. Duofoil shield with 10 AWG (105x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives100 ea, BLACK- Mfr's Part No.: 29503 010100
- IWC Item No.: B-29503-100
-
Belden 29503 0101000 - 10 AWG - 3 C - 1000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
10 AWG (105x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor. Duofoil shield with 10 AWG (105x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives1000 ft, BLACK- Mfr's Part No.: 29503 0101000
- IWC Item No.: B-29503-1000
-
Belden 29503 010250 - 10 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
10 AWG (105x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor. Duofoil shield with 10 AWG (105x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives250 ft, BLACK- Mfr's Part No.: 29503 010250
- IWC Item No.: B-29503-250
-
Belden 29503 010500 - 10 AWG - 3 C - 500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
10 AWG (105x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor. Duofoil shield with 10 AWG (105x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives500 ft, BLACK- Mfr's Part No.: 29503 010500
- IWC Item No.: B-29503-500
-
Belden 29503 0105000 - 10 AWG - 3 C - 5000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
10 AWG (105x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor. Duofoil shield with 10 AWG (105x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives5000 ft, BLACK- Mfr's Part No.: 29503 0105000
- IWC Item No.: B-29503-5000
-
Belden 29504 0101000 - 8 AWG - 3 C - 1000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
8 AWG (7x19x29) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 14 AWG (41x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr1000 ft, BLACK- Mfr's Part No.: 29504 0101000
- IWC Item No.: B-29504-1000
-
Belden 29504 010250 - 8 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
8 AWG (7x19x29) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 14 AWG (41x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr250 ft, BLACK- Mfr's Part No.: 29504 010250
- IWC Item No.: B-29504-250
-
Belden 29504 010500 - 8 AWG - 3 C - 500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
8 AWG (7x19x29) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 14 AWG (41x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr500 ft, BLACK- Mfr's Part No.: 29504 010500
- IWC Item No.: B-29504-500
-
Belden 29504 0105000 - 8 AWG - 3 C - 5000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
8 AWG (7x19x29) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 14 AWG (41x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr5000 ft, BLACK- Mfr's Part No.: 29504 0105000
- IWC Item No.: B-29504-5000
-
Belden 29505 0101000 - 6 AWG - 3 C - 1000 FT - 1000 V RMS - BLACK
6 AWG (7x19x27) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr1000 ft, BLACK- Mfr's Part No.: 29505 0101000
- IWC Item No.: B-29505-1000
-
Belden 29505 010250 - 6 AWG - 3 C - 250 FT - 1000 V RMS - BLACK
6 AWG (7x19x27) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr250 ft, BLACK- Mfr's Part No.: 29505 010250
- IWC Item No.: B-29505-250
-
Belden 29505 0103500 - 6 AWG - 3 C - 3500 FT - 1000 V RMS - BLACK
6 AWG (7x19x27) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr3500 ft, BLACK- Mfr's Part No.: 29505 0103500
- IWC Item No.: B-29505-3500
-
Belden 29506 0101000 - 4 AWG - 3 C - 1000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
4 AWG (7x19x25) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr1000 ft, BLACK- Mfr's Part No.: 29506 0101000
- IWC Item No.: B-29506-1000
-
Belden 29506 010250 - 4 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
4 AWG (7x19x25) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr250 ft, BLACK- Mfr's Part No.: 29506 010250
- IWC Item No.: B-29506-250
-
Belden 29506 0103000 - 4 AWG - 3 C - 3000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
4 AWG (7x19x25) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr3000 ft, BLACK- Mfr's Part No.: 29506 0103000
- IWC Item No.: B-29506-3000
-
Belden 29507 0101000 - 2 AWG - 3 C - 1000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
2 AWG (7x19x23) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 8 AWG (133x) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drive1000 ft, BLACK- Mfr's Part No.: 29507 0101000
- IWC Item No.: B-29507-1000
-
Belden 29507 0102000 - 2 AWG - 3 C - 2000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
2 AWG (7x19x23) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 8 AWG (133x) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drive2000 ft, BLACK- Mfr's Part No.: 29507 0102000
- IWC Item No.: B-29507-10-2000
-
Belden 29507 010250 - 2 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
2 AWG (7x19x23) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 8 AWG (133x) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drive250 ft, BLACK- Mfr's Part No.: 29507 010250
- IWC Item No.: B-29507-10-250
-
Belden 29507 010500 - 2 AWG - 3 C - 500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
2 AWG (7x19x23) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 8 AWG (133x) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drive500 ft, BLACK- Mfr's Part No.: 29507 010500
- IWC Item No.: B-29507-10-500
-
Belden 29528 0101000 - 1 AWG - 3 C - 1000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
1 AWG (7x19x22) tinned copper. 3 conductor. XLPE insulation + three 6 AWG (7x19x27)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.1000 ft, BLACK- Mfr's Part No.: 29528 0101000
- IWC Item No.: B-29528-10-1000
-
Belden 29528 010250 - 1 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
1 AWG (7x19x22) tinned copper. 3 conductor. XLPE insulation + three 6 AWG (7x19x27)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.250 ft, BLACK- Mfr's Part No.: 29528 010250
- IWC Item No.: B-29528-10-250
-
Belden 29528 0103000 - 1 AWG - 3 C - 3000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
1 AWG (7x19x22) tinned copper. 3 conductor. XLPE insulation + three 6 AWG (7x19x27)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.3000 ft, BLACK- Mfr's Part No.: 29528 0103000
- IWC Item No.: B-29528-10-3000
-
Belden 29528 010500 - 1 AWG - 3 C - 500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
1 AWG (7x19x22) tinned copper. 3 conductor. XLPE insulation + three 6 AWG (7x19x27)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.500 ft, BLACK- Mfr's Part No.: 29528 010500
- IWC Item No.: B-29528-10-500
-
Belden 29529 0101000 - 36526 AWG - 3 C - 1000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
1/0 AWG (7x19x21) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.1000 ft, BLACK- Mfr's Part No.: 29529 0101000
- IWC Item No.: B-29529-10-1000
-
Belden 29529 0102000 - 36526 AWG - 3 C - 2000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
1/0 AWG (7x19x21) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.2000 ft, BLACK- Mfr's Part No.: 29529 0102000
- IWC Item No.: B-29529-10-2000
-
Belden 29529 010250 - 36526 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
1/0 AWG (7x19x21) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.250 ft, BLACK- Mfr's Part No.: 29529 010250
- IWC Item No.: B-29529-10-250
-
Belden 29529 010500 - 36526 AWG - 3 C - 500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
1/0 AWG (7x19x21) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.500 ft, BLACK- Mfr's Part No.: 29529 010500
- IWC Item No.: B-29529-10-500
-
Belden 29530 0101000 - 36557 AWG - 3 C - 1000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
2/0 AWG (7x19x20) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.1000 ft, BLACK- Mfr's Part No.: 29530 0101000
- IWC Item No.: B-29530-10-1000
-
Belden 29530 0102000 - 36557 AWG - 3 C - 2000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
2/0 AWG (7x19x20) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.2000 ft, BLACK- Mfr's Part No.: 29530 0102000
- IWC Item No.: B-29530-10-2000
-
Belden 29530 010250 - 36557 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
2/0 AWG (7x19x20) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.250 ft, BLACK- Mfr's Part No.: 29530 010250
- IWC Item No.: B-29530-10-250
-
Belden 29530 010500 - 36557 AWG - 3 C - 500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
2/0 AWG (7x19x20) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.500 ft, BLACK- Mfr's Part No.: 29530 010500
- IWC Item No.: B-29530-10-500
-
Belden 29531 0101000 - 36586 AWG - 3 C - 1000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
3/0 AWG (19x7x19) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.1000 ft, BLACK- Mfr's Part No.: 29531 0101000
- IWC Item No.: B-29531-10-1000
-
Belden 29531 0102000 - 36586 AWG - 3 C - 2000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
3/0 AWG (19x7x19) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.2000 ft, BLACK- Mfr's Part No.: 29531 0102000
- IWC Item No.: B-29531-10-2000
-
Belden 29531 010250 - 36586 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
3/0 AWG (19x7x19) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.250 ft, BLACK- Mfr's Part No.: 29531 010250
- IWC Item No.: B-29531-10-250
-
Belden 29531 010500 - 36586 AWG - 3 C - 500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
3/0 AWG (19x7x19) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.500 ft, BLACK- Mfr's Part No.: 29531 010500
- IWC Item No.: B-29531-10-500
-
Belden 29532 0101500 - 36617 AWG - 3 C - 1500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
4/0 AWG (19x7x18) tinned copper. 3 conductor. XLPE insulation + three 2 AWG (7x19x23)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.1500 ft, BLACK- Mfr's Part No.: 29532 0101500
- IWC Item No.: B-29532-10-1500
-
Belden 29532 010250 - 36617 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
4/0 AWG (19x7x18) tinned copper. 3 conductor. XLPE insulation + three 2 AWG (7x19x23)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.250 ft, BLACK- Mfr's Part No.: 29532 010250
- IWC Item No.: B-29532-10-250
-
Belden 29532 010500 - 36617 AWG - 3 C - 500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK
4/0 AWG (19x7x18) tinned copper. 3 conductor. XLPE insulation + three 2 AWG (7x19x23)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.500 ft, BLACK- Mfr's Part No.: 29532 010500
- IWC Item No.: B-29532-10-500
-
Belden 5120FL D151000 - 14 AWG - 2 C - 1000 FT - 300 V RMS - BLUE
14 AWG SOLID BARE COPPER. PVC INSULATION. TWO SINGLES TWISTED WITH BELDFOIL SHIELD. 22 AWG SOLID TINNED COPPER DRAIN WIRE. PVC JACKET.1000 ft, BLUE- Mfr's Part No.: 5120FL D151000
- IWC Item No.: B-5120FL-1000
-
Belden 5202F1 0021000 - 16 AWG - 4 C - 1000 EA - 300 V RMS - RED
16 AWG (7X24) tinned copper. PVC insulated. four conductors. shielded. PVC jacket.1000 ea, RED- Mfr's Part No.: 5202F1 0021000
- IWC Item No.: B-5202F1-2-1000
-
Belden 5202F1 0101000 - 16 AWG - 4 C - 1000 EA - 300 V RMS - BLACK
16 AWG (7X24) tinned copper. PVC insulated. four conductors. shielded. PVC jacket.1000 ea, BLACK- Mfr's Part No.: 5202F1 0101000
- IWC Item No.: B-5202F1-10-1000
-
Belden 5220FL 0021000 - 16 AWG - 2 C - 1000 FT - 300 V RMS - RED
16 AWG SOLID BARE COPPER. PP INSULATION. TWO SINGLES TWISTED WITH BELDFOIL SHIELD. 20 AWG STRANDED TINNED COPPER DRAIN WIRE. PVC JACKET. FIRE ALARM.1000 ft, RED- Mfr's Part No.: 5220FL 0021000
- IWC Item No.: B-5220FL-2-1000
-
Belden 5320FL 002U1000 - 18 AWG - 2 C - U1000 FT - 300 V RMS - RED
18 AWG SOLID BARE COPPER. PP INSULATION. TWO CONDUCTORS TWISTED. BELDFOIL SHIELDED WITH 24 AWG SOLID TINNED COPPER DRAIN WIRE. PVC JACKET. FIRE ALARM.u1000 ft, RED- Mfr's Part No.: 5320FL 002U1000
- IWC Item No.: B-5320FL-2-U1000
-
Belden 5320FL D15U1000 - 18 AWG - 2 C - U1000 FT - 300 V RMS - BLUE
18 AWG SOLID BARE COPPER. PP INSULATION. TWO CONDUCTORS TWISTED. BELDFOIL SHIELDED WITH 24 AWG SOLID TINNED COPPER DRAIN WIRE. PVC JACKET. FIRE ALARM.u1000 ft, BLUE- Mfr's Part No.: 5320FL D15U1000
- IWC Item No.: B-5320FL-U1000
-
Belden 5320FM 0021000 - 18 AWG - 2 C - 1000 EA - 300 V RMS - RED
CIRCUIT INTEGRITY CABLE: 18 AWG SOLID BARE COPPER. THERMOSET ELASTOMER INSULATION. TWO CONDUCTORS. POLYESTER/ALUMINUM Beldfoil SHIELD. #20 AWG TINNED COPPER DRAIN WIRE. LSZH FRPE JACKET. FIRE ALARM.1000 ea, RED- Mfr's Part No.: 5320FM 0021000
- IWC Item No.: B-5320FM-2-1000
-
Belden 600V C-TC+ Control Cables for Extreme Flexing, Shielded
Belden Infinity® Flexible Automation Cable
-
Belden 6100FE 8771000 - 14 AWG - 2 C - 1000 FT - 150 V RMS - NATURAL
14 AWG (19x27) bare copper. Flamarrest insulation. two singles twisted. Beldfoil shielded (foil out) with 22 AWG tinned copper drain wire. Flamarrest jacket with ripcord. Sequential footage marking every two feet.1000 ft, NATURAL- Mfr's Part No.: 6100FE 8771000
- IWC Item No.: B-6100FE-1000
-
Belden 6220FL 0021000 - 16 AWG - 2 C - 1000 FT - 300 V RMS - RED
16 AWG Solid bare copper conductor with flamarrest insulation. two singles twisted. Beldfoil shielded (foil side out plus 24 awg drain). flamarrest jacket1000 ft, RED- Mfr's Part No.: 6220FL 0021000
- IWC Item No.: B-6220FL-1000
-
Belden 6500FE 8771000 - 22 AWG - 2 C - 1000 FT - 300 V RMS - NATURAL
22 AWG 7X30 BARE COPPER. 2 CONDUCTORS. FLAMARREST INSULATED. FOIL SHIELDED. FOIL SIDE OUT PLUS 24 AWG DRAIN. FLAMARREST JACKET WITH RIP CORD. SEQUENTAIL NUMBERING EVERY TWO FEET.1000 ft, NATURAL- Mfr's Part No.: 6500FE 8771000
- IWC Item No.: B-6500FE-877-1000
-
Belden 6500PE 0091000 - 22 AWG - 2 C - 1000 EA - 300 V RMS - WHITE
22 AWG 7X30 TINNED COPPER. 2 CONDUCTORS. FLAMARREST INSULATED. FOIL SHIELDED. FOIL SIDE IN PLUS 24 AWG DRAIN. FLAMARREST JACKET BONDED TO SHIELD TAPE. SEQUENTAIL NUMBERING EVERY TWO FEET.1000 ea, WHITE- Mfr's Part No.: 6500PE 0091000
- IWC Item No.: B-6500PE-9-1000
-
Belden 6500PE 0101000 - 22 AWG - 2 C - 1000 EA - 300 V RMS - BLACK
22 AWG 7X30 TINNED COPPER. 2 CONDUCTORS. FLAMARREST INSULATED. FOIL SHIELDED. FOIL SIDE IN PLUS 24 AWG DRAIN. FLAMARREST JACKET BONDED TO SHIELD TAPE. SEQUENTAIL NUMBERING EVERY TWO FEET.1000 ea, BLACK- Mfr's Part No.: 6500PE 0101000
- IWC Item No.: B-6500PE-10-1000
-
Belden 7929A 0102000 - 24 AWG - C - 2000 EA - 300 V RMS - BLACK
Industrial Ethernet Cable. 4 Pair ScTP. 200MHz Category 5e. Riser Rated. #24 Solid Bare Copper. Polyolefin Insulation Singles Adjoined. Foil Shield Bonded to PVC Jacket. Sequential Marking at Two Foot Intervals2000 ea, BLACK- Mfr's Part No.: 7929A 0102000
- IWC Item No.: B-7929A-10-2000
-
Belden 7938A B59500 - 24 AWG - C - 500 FT - 300 V RMS - BLACK/MATTE
500 ft, BLACK/MATTE- Mfr's Part No.: 7938A B59500
- IWC Item No.: B-7938A-B59-500
-
Belden 8307 0601000 - 22 AWG - C - 1000 EA - 300 V RMS (UL AWM Style 2464) - CHROME
22 AWG (7x30) Tinned Copper. 7 Pairs. S-R PVC insulation. overall Polyester/Alum Tape Plus 65% Tinned Copper Braid Shield. PVC Jacket.1000 ea, CHROME- Mfr's Part No.: 8307 0601000
- IWC Item No.: B-8307-1000
-
Belden 83394 002500 - 22 AWG - 2 C - 500 FT - 2000 V DC^350 V RMS - RED
22 AWG (7x30) tinned copper. FEP insulation. two conductors. conductive nylon plus Beldfoil shield with 22 AWG (7x30) tinned copper drain wire. silicone jacket.500 ft, RED- Mfr's Part No.: 83394 002500
- IWC Item No.: B-83394-500
-
Belden 8437 0101000 - 22 AWG - C - 1000 EA - 300 V RMS (UL AWM Style 2095) - BLACK
22 AWG solid tinned copper. 1 pair. PVC insulated. overall polyester tape + 88% tinned copper braid shield with 22 awg solid tinned copper drain wire. PVC jacket.1000 ea, BLACK- Mfr's Part No.: 8437 0101000
- IWC Item No.: B-8437-1000
-
Belden 8728 0601000 - 22 AWG - C - 1000 EA - 300 V RMS (UL AWM Style 2717) - CHROME
2 PAIRS INDIVIDUALLY SHIELDED 22 AWG (7X30) TINNED COPPER. POLYPROPYLENE INSULATED. CABLED ON COMMON AXIS. PVC JACKET1000 ea, CHROME- Mfr's Part No.: 8728 0601000
- IWC Item No.: B-8728-1000
-
-
-
-
-
-
-
Belden 87760 0021000 - 18 AWG - C - 1000 FT - 300 V RMS - RED
18 AWG (19X30) TINNED COPPER. 2 CONDUCTORS. FEP INSULATED. ALUMINUM/MYLAR SHIELDED (FOIL OUT PLUS 20 AWG DRAIN). FLUOROCOPOLYMER JACKETED1000 ft, RED- Mfr's Part No.: 87760 0021000
- IWC Item No.: B-87760-1000
-
Belden 8786 060500 - 24^22 AWG - 4^2 C - 500 EA - 300 V RMS - CHROME
24 & 22 AWG (7X32 & 7X30) TC. VINYL INSULATED 4 CONDRS.(24 AWG) WITH OVERALL FOIL TAPE SHIELD. 2 CONDUCTORS UNSHIELDED. OVERALL CHROME PVC JACKET500 ea, CHROME- Mfr's Part No.: 8786 060500
- IWC Item No.: B-8786-500
-
Belden 8786 060U500 - 24^22 AWG - 4^2 C - U500 EA - 300 V RMS - CHROME
24 & 22 AWG (7X32 & 7X30) TC. VINYL INSULATED 4 CONDRS.(24 AWG) WITH OVERALL FOIL TAPE SHIELD. 2 CONDUCTORS UNSHIELDED. OVERALL CHROME PVC JACKETu500 ea, CHROME- Mfr's Part No.: 8786 060U500
- IWC Item No.: B-8786-U500
-
Belden 8787 060500 - 24^22 AWG - 8^2 C - 500 EA - 350 V RMS - CHROME
24 & 22 AWG (7X32 & 7X30) TC. 8 24 AWG CONDRS POLYETHYLENE INSUL.. 2 22 AWG CONDRS.. PVC INSULATED TWO QUADS OF 24 AWG CONDRS.-EACH QUAD WITH FOIL TAPE SHIELD. OVERALL CHROME PVC JACKET500 ea, CHROME- Mfr's Part No.: 8787 060500
- IWC Item No.: B-8787-500
-
Belden 8787 060U500 - 24^22 AWG - 8^2 C - U500 EA - 350 V RMS - CHROME
24 & 22 AWG (7X32 & 7X30) TC. 8 24 AWG CONDRS POLYETHYLENE INSUL.. 2 22 AWG CONDRS.. PVC INSULATED TWO QUADS OF 24 AWG CONDRS.-EACH QUAD WITH FOIL TAPE SHIELD. OVERALL CHROME PVC JACKETu500 ea, CHROME- Mfr's Part No.: 8787 060U500
- IWC Item No.: B-8787-U500
-
Belden 88107 008500 - 24 AWG - 1 C - 500 FT - 300 V RMS - GRAY
24 AWG stranded (7x32) tinned copper. 7-1/2 pairs. Foam Fep Insulation. overall 100% Beldfoil shield + 24 AWG (7x32) tinned copper drain wire. fluorocopolymer Jacket.500 ft, GRAY- Mfr's Part No.: 88107 008500
- IWC Item No.: B-88107-500
-
Items 1 to 100 of 175 total
- 1
- 2