Shielded Multi-Conductor

We offer a range of Multi-Conductor Shielded Cables in an assortment of different gage sizes, dimensions, insulation, jacketing and shielding materials to ensure we meet the technical requirements of our customers. 2 Conducted Shielded Cables basically mean the cable has a cover to protect from signal interference. Multi-Conductor Sheilded cables are also known as twisted pair cables.

Materials for Multi-Conductor Shielded Cable:

  • Tinned copper braid
  • Spiral copper tape
  • Beldfoil
  • Aluminum foil-polyester tape
  • Silver-plated copper
  • Silver-plated copper braid shields

Applications of 2 Conductor Shielded Cables:

Our range of shielded multi-conductor cables are ideal for a number of different industrial applications such as:

  • Computers
  • Communications
  • Instrumentation
  • Audio
  • Control & data transfer
  • Fire & security alarms

Contact us to learn more about Multi-Conductor Shielded Cables.

Items 1 to 100 of 175 total

Page:
  1. 1
  2. 2
  1. ,
    • Mfr's Part No.: 8872MN 
    • IWC Item No.: B-8872MN 
  2. Alpha Wire Communication and Control Cable, Braid Shield, Rubber

    Alpha Wire Communication and Control Cable, Braid Shield, Rubber

    Tinned Copper Conductors. EPDM Rubber Insulation. Polychloroprene Jacket.

  3. Alpha Wire Communication and Control, Multiconductor, Overall Foil/Braid

    Alpha Wire Communication and Control, Multiconductor, Overall Foil/Braid

    Tinned Copper Conductors. S-R PVC Insulation. PVC Jacket.

  4. Alpha Wire Communication, Control and Industrial Cable, Foil Shield

    Alpha Wire Communication, Control and Industrial Cable, Foil Shield

    300V Foil Shield, Multiconductor Communication and Control Cable.

  5. Alpha Wire Communication, Control and Industrial Cable, Multiconductor

    Alpha Wire Communication, Control and Industrial Cable, Multiconductor

    Bare Copper Conductors. Plenum-Rated PVC Insulation and Jacket.

  6. Alpha Wire Communication, Control Cable, Multicond, Braid Shield, 600V

    Alpha Wire Communication, Control Cable, Multicond, Braid Shield, 600V

    Tinned Copper. PTFE Insulation. Braid Shield. PTFE Tape Jacket

  7. Alpha Wire Xtra-Guard® 1, Foil Shield, 300V

    Alpha Wire Xtra-Guard® 1, Foil Shield, 300V

    Tinned Copper Conductors. PVC Insulation. PVC Jacket.

  8. Alpha Wire Xtra-Guard® 1, Supra-Shield® Foil/Braid, 300V

    Alpha Wire Xtra-Guard® 1, Supra-Shield® Foil/Braid, 300V

    Tinned Copper Conductors. PVC Insulation. PVC Jacket.

  9. Alpha Wire Xtra-Guard® 1, Supra-Shield® Foil/Braid, 600V

    Alpha Wire Xtra-Guard® 1, Supra-Shield® Foil/Braid, 600V

    Tinned Copper Conductors. PVC Insulation. PVC Jacket.

  10. Alpha Wire Xtra-Guard® 3, Direct Burial, Foil Shield, 300 V

    Alpha Wire Xtra-Guard® 3, Direct Burial, Foil Shield, 300 V

    Tinned Copper Conductors. PVC Insulation. PE Jacket.

  11. Alpha Wire Xtra-Guard® 4, Advanced Temp. and Chemical Performance,  Foil

    Alpha Wire Xtra-Guard® 4, Advanced Temp. and Chemical Performance, Foil

    Tinned Copper Conductors. TPE Insulation. TPE Jacket. (Blk Std, 9 colors avail.).

  12. Alpha Wire Xtra-Guard® 4, Advanced Temp. and Chemical Performance, 300V

    Alpha Wire Xtra-Guard® 4, Advanced Temp. and Chemical Performance, 300V

    Tinned Copper Conductors. TPE Insulation. TPE Jacket. (Blk Std, 9 colors avail.).

  13. Alpha Wire Xtra-Guard® Continuous Flex, Foil/Spiral Shield, 300V

    Alpha Wire Xtra-Guard® Continuous Flex, Foil/Spiral Shield, 300V

    Tinned Copper. Lubricated S-R PVC Insulation. Oil-Resistant PVC Jacket.

  14. Belden 1000V Flexible Motor Supply Cable, 3 Conductor

    Belden 1000V Flexible Motor Supply Cable, 3 Conductor

    Tinned Copper. XLPE Insulation. Shielded. 90°C Wet/Dry. 1000V.

  15. Belden 1000V Flexible Motor Supply Cable, 4 Conductor

    Belden 1000V Flexible Motor Supply Cable, 4 Conductor

    Tinned Copper. XLPE Insulation. Shielded. 90°C Wet/Dry. 1000V.

  16. Belden 1348A 0021000 - 20 AWG - 3 C - 1000 EA - 300 V RMS - RED

    MITSUBISHI CC LINK SIGNAL CABLE - 3 CONDUCTOR 20 AWG (7X28) BARE COPPER. FOAMED PE INSULATION. OVERALL BELDFOIL SHIELD WITH A 22 AWG (19X34) TINNED COPPER DRAIN WIRE. 78% TINNED COPPER BRAID. PVC INNER JACKET.
    1000 ea, RED
    • Mfr's Part No.: 1348A 0021000
    • IWC Item No.: B-1348A-1000
  17. Belden 1349A 0021000 - 18^20 AWG - 2^3 C - 1000 EA - 300 V RMS^300 V RMS - RED

    MITSUBISHI CC LINK SIGNAL & POWER CABLE - 3 CONDUCTOR 20 AWG (7X28) BARE COPPER. FOAMED PE INSULATION. OVERALL BELDFOIL SHIELD WITH A 22 AWG (19X34) TINNED COPPER DRAIN WIRE. 78% TINNED COPPER BRAID. PVC INNER JACKET. TWO CONDUCTORS 18 AWG (7X26) BARE COP
    1000 ea, RED
    • Mfr's Part No.: 1349A 0021000
    • IWC Item No.: B-1349A-2-1000
  18. Belden 1526A 01010000 - 20 AWG - 3 C - 10000 FT - 300 V RMS - BLACK

    20 AWG (7X#28) Bare COPPER. PVC INSULATION. BELDFOIL(R) 100%. 22 AWG (7X#30) TINNED COPPER DRAIN WIRE. PVC JACKET WITH NYLON RIPCORD.
    10000 ft, BLACK
    • Mfr's Part No.: 1526A 01010000
    • IWC Item No.: B-1526A-10000
  19. Belden 1540A 0081000 - 28 AWG - 7 C - 1000 FT - 150 V RMS - GRAY

    28 AWG (7x36) Bare copper. multiconductor cable. 7 conductors step insulated with solid PP and solid PE. overall Beldfoil shield with 28 AWG (7x36) tinned copper drain wire. tinned copper braid. PVC jacket.
    1000 ft, GRAY
    • Mfr's Part No.: 1540A 0081000
    • IWC Item No.: B-1540A-1000
  20. Belden 2000V-UL-Flexible-Motor-Supply-Cable

    Belden 2000V-UL-Flexible-Motor-Supply-Cable

    Tinned Copper Conductors. XLPE Insulation. 90°C Wet/Dry. 2000V.

  21. Belden 29501 010100 - 14 AWG - 3 C - 100 EA - 1000 V RMS - BLACK

    14 AWG (41x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 14 AWG (41x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.
    100 ea, BLACK
    • Mfr's Part No.: 29501 010100
    • IWC Item No.: B-29501-100
  22. Belden 29501 0101000 - 14 AWG - 3 C - 1000 FT - 1000 V RMS - BLACK

    14 AWG (41x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 14 AWG (41x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.
    1000 ft, BLACK
    • Mfr's Part No.: 29501 0101000
    • IWC Item No.: B-29501-1000
  23. Belden 29501 010250 - 14 AWG - 3 C - 250 FT - 1000 V RMS - BLACK

    14 AWG (41x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 14 AWG (41x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.
    250 ft, BLACK
    • Mfr's Part No.: 29501 010250
    • IWC Item No.: B-29501-250
  24. Belden 29501 010500 - 14 AWG - 3 C - 500 FT - 1000 V RMS - BLACK

    14 AWG (41x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 14 AWG (41x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.
    500 ft, BLACK
    • Mfr's Part No.: 29501 010500
    • IWC Item No.: B-29501-500
  25. Belden 29501 0105000 - 14 AWG - 3 C - 5000 FT - 1000 V RMS - BLACK

    14 AWG (41x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 14 AWG (41x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.
    5000 ft, BLACK
    • Mfr's Part No.: 29501 0105000
    • IWC Item No.: B-29501-5000
  26. Belden 29502 010100 - 12 AWG - 3 C - 100 EA - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    12 AWG (65x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.
    100 ea, BLACK
    • Mfr's Part No.: 29502 010100
    • IWC Item No.: B-29502-100
  27. Belden 29502 0101000 - 12 AWG - 3 C - 1000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    12 AWG (65x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.
    1000 ft, BLACK
    • Mfr's Part No.: 29502 0101000
    • IWC Item No.: B-29502-1000
  28. Belden 29502 010250 - 12 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    12 AWG (65x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.
    250 ft, BLACK
    • Mfr's Part No.: 29502 010250
    • IWC Item No.: B-29502-250
  29. Belden 29502 010500 - 12 AWG - 3 C - 500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    12 AWG (65x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.
    500 ft, BLACK
    • Mfr's Part No.: 29502 010500
    • IWC Item No.: B-29502-500
  30. Belden 29502 0105000 - 12 AWG - 3 C - 5000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    12 AWG (65x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor Duofoil shield with 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives.
    5000 ft, BLACK
    • Mfr's Part No.: 29502 0105000
    • IWC Item No.: B-29502-5000
  31. Belden 29503 010100 - 10 AWG - 3 C - 100 EA - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    10 AWG (105x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor. Duofoil shield with 10 AWG (105x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives
    100 ea, BLACK
    • Mfr's Part No.: 29503 010100
    • IWC Item No.: B-29503-100
  32. Belden 29503 0101000 - 10 AWG - 3 C - 1000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    10 AWG (105x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor. Duofoil shield with 10 AWG (105x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives
    1000 ft, BLACK
    • Mfr's Part No.: 29503 0101000
    • IWC Item No.: B-29503-1000
  33. Belden 29503 010250 - 10 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    10 AWG (105x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor. Duofoil shield with 10 AWG (105x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives
    250 ft, BLACK
    • Mfr's Part No.: 29503 010250
    • IWC Item No.: B-29503-250
  34. Belden 29503 010500 - 10 AWG - 3 C - 500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    10 AWG (105x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor. Duofoil shield with 10 AWG (105x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives
    500 ft, BLACK
    • Mfr's Part No.: 29503 010500
    • IWC Item No.: B-29503-500
  35. Belden 29503 0105000 - 10 AWG - 3 C - 5000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    10 AWG (105x30) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated ground conductor. Duofoil shield with 10 AWG (105x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drives
    5000 ft, BLACK
    • Mfr's Part No.: 29503 0105000
    • IWC Item No.: B-29503-5000
  36. Belden 29504 0101000 - 8 AWG - 3 C - 1000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    8 AWG (7x19x29) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 14 AWG (41x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr
    1000 ft, BLACK
    • Mfr's Part No.: 29504 0101000
    • IWC Item No.: B-29504-1000
  37. Belden 29504 010250 - 8 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    8 AWG (7x19x29) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 14 AWG (41x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr
    250 ft, BLACK
    • Mfr's Part No.: 29504 010250
    • IWC Item No.: B-29504-250
  38. Belden 29504 010500 - 8 AWG - 3 C - 500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    8 AWG (7x19x29) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 14 AWG (41x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr
    500 ft, BLACK
    • Mfr's Part No.: 29504 010500
    • IWC Item No.: B-29504-500
  39. Belden 29504 0105000 - 8 AWG - 3 C - 5000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    8 AWG (7x19x29) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 14 AWG (41x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr
    5000 ft, BLACK
    • Mfr's Part No.: 29504 0105000
    • IWC Item No.: B-29504-5000
  40. Belden 29505 0101000 - 6 AWG - 3 C - 1000 FT - 1000 V RMS - BLACK

    6 AWG (7x19x27) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr
    1000 ft, BLACK
    • Mfr's Part No.: 29505 0101000
    • IWC Item No.: B-29505-1000
  41. Belden 29505 010250 - 6 AWG - 3 C - 250 FT - 1000 V RMS - BLACK

    6 AWG (7x19x27) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr
    250 ft, BLACK
    • Mfr's Part No.: 29505 010250
    • IWC Item No.: B-29505-250
  42. Belden 29505 0103500 - 6 AWG - 3 C - 3500 FT - 1000 V RMS - BLACK

    6 AWG (7x19x27) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr
    3500 ft, BLACK
    • Mfr's Part No.: 29505 0103500
    • IWC Item No.: B-29505-3500
  43. Belden 29506 0101000 - 4 AWG - 3 C - 1000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    4 AWG (7x19x25) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr
    1000 ft, BLACK
    • Mfr's Part No.: 29506 0101000
    • IWC Item No.: B-29506-1000
  44. Belden 29506 010250 - 4 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    4 AWG (7x19x25) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr
    250 ft, BLACK
    • Mfr's Part No.: 29506 010250
    • IWC Item No.: B-29506-250
  45. Belden 29506 0103000 - 4 AWG - 3 C - 3000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    4 AWG (7x19x25) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 12 AWG (65x30) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency dr
    3000 ft, BLACK
    • Mfr's Part No.: 29506 0103000
    • IWC Item No.: B-29506-3000
  46. Belden 29507 0101000 - 2 AWG - 3 C - 1000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    2 AWG (7x19x23) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 8 AWG (133x) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drive
    1000 ft, BLACK
    • Mfr's Part No.: 29507 0101000
    • IWC Item No.: B-29507-1000
  47. Belden 29507 0102000 - 2 AWG - 3 C - 2000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    2 AWG (7x19x23) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 8 AWG (133x) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drive
    2000 ft, BLACK
    • Mfr's Part No.: 29507 0102000
    • IWC Item No.: B-29507-10-2000
  48. Belden 29507 010250 - 2 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    2 AWG (7x19x23) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 8 AWG (133x) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drive
    250 ft, BLACK
    • Mfr's Part No.: 29507 010250
    • IWC Item No.: B-29507-10-250
  49. Belden 29507 010500 - 2 AWG - 3 C - 500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    2 AWG (7x19x23) tinned copper. 3 conductor. XLPE insulation + 1 PVC insulated Ground conductor. Duofoil shield with four 8 AWG (133x) tinned copper drain wire. 85% braid coverage. PVC jacket. This product is intended for use with variable frequency drive
    500 ft, BLACK
    • Mfr's Part No.: 29507 010500
    • IWC Item No.: B-29507-10-500
  50. Belden 29528 0101000 - 1 AWG - 3 C - 1000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    1 AWG (7x19x22) tinned copper. 3 conductor. XLPE insulation + three 6 AWG (7x19x27)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    1000 ft, BLACK
    • Mfr's Part No.: 29528 0101000
    • IWC Item No.: B-29528-10-1000
  51. Belden 29528 010250 - 1 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    1 AWG (7x19x22) tinned copper. 3 conductor. XLPE insulation + three 6 AWG (7x19x27)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    250 ft, BLACK
    • Mfr's Part No.: 29528 010250
    • IWC Item No.: B-29528-10-250
  52. Belden 29528 0103000 - 1 AWG - 3 C - 3000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    1 AWG (7x19x22) tinned copper. 3 conductor. XLPE insulation + three 6 AWG (7x19x27)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    3000 ft, BLACK
    • Mfr's Part No.: 29528 0103000
    • IWC Item No.: B-29528-10-3000
  53. Belden 29528 010500 - 1 AWG - 3 C - 500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    1 AWG (7x19x22) tinned copper. 3 conductor. XLPE insulation + three 6 AWG (7x19x27)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    500 ft, BLACK
    • Mfr's Part No.: 29528 010500
    • IWC Item No.: B-29528-10-500
  54. Belden 29529 0101000 - 36526 AWG - 3 C - 1000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    1/0 AWG (7x19x21) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    1000 ft, BLACK
    • Mfr's Part No.: 29529 0101000
    • IWC Item No.: B-29529-10-1000
  55. Belden 29529 0102000 - 36526 AWG - 3 C - 2000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    1/0 AWG (7x19x21) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    2000 ft, BLACK
    • Mfr's Part No.: 29529 0102000
    • IWC Item No.: B-29529-10-2000
  56. Belden 29529 010250 - 36526 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    1/0 AWG (7x19x21) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    250 ft, BLACK
    • Mfr's Part No.: 29529 010250
    • IWC Item No.: B-29529-10-250
  57. Belden 29529 010500 - 36526 AWG - 3 C - 500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    1/0 AWG (7x19x21) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    500 ft, BLACK
    • Mfr's Part No.: 29529 010500
    • IWC Item No.: B-29529-10-500
  58. Belden 29530 0101000 - 36557 AWG - 3 C - 1000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    2/0 AWG (7x19x20) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    1000 ft, BLACK
    • Mfr's Part No.: 29530 0101000
    • IWC Item No.: B-29530-10-1000
  59. Belden 29530 0102000 - 36557 AWG - 3 C - 2000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    2/0 AWG (7x19x20) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    2000 ft, BLACK
    • Mfr's Part No.: 29530 0102000
    • IWC Item No.: B-29530-10-2000
  60. Belden 29530 010250 - 36557 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    2/0 AWG (7x19x20) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    250 ft, BLACK
    • Mfr's Part No.: 29530 010250
    • IWC Item No.: B-29530-10-250
  61. Belden 29530 010500 - 36557 AWG - 3 C - 500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    2/0 AWG (7x19x20) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    500 ft, BLACK
    • Mfr's Part No.: 29530 010500
    • IWC Item No.: B-29530-10-500
  62. Belden 29531 0101000 - 36586 AWG - 3 C - 1000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    3/0 AWG (19x7x19) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    1000 ft, BLACK
    • Mfr's Part No.: 29531 0101000
    • IWC Item No.: B-29531-10-1000
  63. Belden 29531 0102000 - 36586 AWG - 3 C - 2000 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    3/0 AWG (19x7x19) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    2000 ft, BLACK
    • Mfr's Part No.: 29531 0102000
    • IWC Item No.: B-29531-10-2000
  64. Belden 29531 010250 - 36586 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    3/0 AWG (19x7x19) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    250 ft, BLACK
    • Mfr's Part No.: 29531 010250
    • IWC Item No.: B-29531-10-250
  65. Belden 29531 010500 - 36586 AWG - 3 C - 500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    3/0 AWG (19x7x19) tinned copper. 3 conductor. XLPE insulation + three 4 AWG (7x19x25)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    500 ft, BLACK
    • Mfr's Part No.: 29531 010500
    • IWC Item No.: B-29531-10-500
  66. Belden 29532 0101500 - 36617 AWG - 3 C - 1500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    4/0 AWG (19x7x18) tinned copper. 3 conductor. XLPE insulation + three 2 AWG (7x19x23)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    1500 ft, BLACK
    • Mfr's Part No.: 29532 0101500
    • IWC Item No.: B-29532-10-1500
  67. Belden 29532 010250 - 36617 AWG - 3 C - 250 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    4/0 AWG (19x7x18) tinned copper. 3 conductor. XLPE insulation + three 2 AWG (7x19x23)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    250 ft, BLACK
    • Mfr's Part No.: 29532 010250
    • IWC Item No.: B-29532-10-250
  68. Belden 29532 010500 - 36617 AWG - 3 C - 500 FT - 1000 V RMS (Flexible Motor Supply Cable)^ 600 V RMS (NEC Type TC) - BLACK

    4/0 AWG (19x7x18) tinned copper. 3 conductor. XLPE insulation + three 2 AWG (7x19x23)Ground conductors. two spirally applied .002 copper shield tapes. PVC jacket. This product is intended for use with variable frequency drives.
    500 ft, BLACK
    • Mfr's Part No.: 29532 010500
    • IWC Item No.: B-29532-10-500
  69. Belden 5120FL D151000 - 14 AWG - 2 C - 1000 FT - 300 V RMS - BLUE

    14 AWG SOLID BARE COPPER. PVC INSULATION. TWO SINGLES TWISTED WITH BELDFOIL SHIELD. 22 AWG SOLID TINNED COPPER DRAIN WIRE. PVC JACKET.
    1000 ft, BLUE
    • Mfr's Part No.: 5120FL D151000
    • IWC Item No.: B-5120FL-1000
  70. Belden 5202F1 0021000 - 16 AWG - 4 C - 1000 EA - 300 V RMS - RED

    16 AWG (7X24) tinned copper. PVC insulated. four conductors. shielded. PVC jacket.
    1000 ea, RED
    • Mfr's Part No.: 5202F1 0021000
    • IWC Item No.: B-5202F1-2-1000
  71. Belden 5202F1 0101000 - 16 AWG - 4 C - 1000 EA - 300 V RMS - BLACK

    16 AWG (7X24) tinned copper. PVC insulated. four conductors. shielded. PVC jacket.
    1000 ea, BLACK
    • Mfr's Part No.: 5202F1 0101000
    • IWC Item No.: B-5202F1-10-1000
  72. Belden 5220FL 0021000 - 16 AWG - 2 C - 1000 FT - 300 V RMS - RED

    16 AWG SOLID BARE COPPER. PP INSULATION. TWO SINGLES TWISTED WITH BELDFOIL SHIELD. 20 AWG STRANDED TINNED COPPER DRAIN WIRE. PVC JACKET. FIRE ALARM.
    1000 ft, RED
    • Mfr's Part No.: 5220FL 0021000
    • IWC Item No.: B-5220FL-2-1000
  73. Belden 5320FL 002U1000 - 18 AWG - 2 C - U1000 FT - 300 V RMS - RED

    18 AWG SOLID BARE COPPER. PP INSULATION. TWO CONDUCTORS TWISTED. BELDFOIL SHIELDED WITH 24 AWG SOLID TINNED COPPER DRAIN WIRE. PVC JACKET. FIRE ALARM.
    u1000 ft, RED
    • Mfr's Part No.: 5320FL 002U1000
    • IWC Item No.: B-5320FL-2-U1000
  74. Belden 5320FL D15U1000 - 18 AWG - 2 C - U1000 FT - 300 V RMS - BLUE

    18 AWG SOLID BARE COPPER. PP INSULATION. TWO CONDUCTORS TWISTED. BELDFOIL SHIELDED WITH 24 AWG SOLID TINNED COPPER DRAIN WIRE. PVC JACKET. FIRE ALARM.
    u1000 ft, BLUE
    • Mfr's Part No.: 5320FL D15U1000
    • IWC Item No.: B-5320FL-U1000
  75. Belden 5320FM 0021000 - 18 AWG - 2 C - 1000 EA - 300 V RMS - RED

    CIRCUIT INTEGRITY CABLE: 18 AWG SOLID BARE COPPER. THERMOSET ELASTOMER INSULATION. TWO CONDUCTORS. POLYESTER/ALUMINUM Beldfoil SHIELD. #20 AWG TINNED COPPER DRAIN WIRE. LSZH FRPE JACKET. FIRE ALARM.
    1000 ea, RED
    • Mfr's Part No.: 5320FM 0021000
    • IWC Item No.: B-5320FM-2-1000
  76. Belden 600V C-TC+ Control Cables for Extreme Flexing, Shielded

    Belden 600V C-TC+ Control Cables for Extreme Flexing, Shielded

    Belden Infinity® Flexible Automation Cable

  77. Belden 6100FE 8771000 - 14 AWG - 2 C - 1000 FT - 150 V RMS - NATURAL

    14 AWG (19x27) bare copper. Flamarrest insulation. two singles twisted. Beldfoil shielded (foil out) with 22 AWG tinned copper drain wire. Flamarrest jacket with ripcord. Sequential footage marking every two feet.
    1000 ft, NATURAL
    • Mfr's Part No.: 6100FE 8771000
    • IWC Item No.: B-6100FE-1000
  78. Belden 6220FL 0021000 - 16 AWG - 2 C - 1000 FT - 300 V RMS - RED

    16 AWG Solid bare copper conductor with flamarrest insulation. two singles twisted. Beldfoil shielded (foil side out plus 24 awg drain). flamarrest jacket
    1000 ft, RED
    • Mfr's Part No.: 6220FL 0021000
    • IWC Item No.: B-6220FL-1000
  79. Belden 6500FE 8771000 - 22 AWG - 2 C - 1000 FT - 300 V RMS - NATURAL

    22 AWG 7X30 BARE COPPER. 2 CONDUCTORS. FLAMARREST INSULATED. FOIL SHIELDED. FOIL SIDE OUT PLUS 24 AWG DRAIN. FLAMARREST JACKET WITH RIP CORD. SEQUENTAIL NUMBERING EVERY TWO FEET.
    1000 ft, NATURAL
    • Mfr's Part No.: 6500FE 8771000
    • IWC Item No.: B-6500FE-877-1000
  80. Belden 6500PE 0091000 - 22 AWG - 2 C - 1000 EA - 300 V RMS - WHITE

    22 AWG 7X30 TINNED COPPER. 2 CONDUCTORS. FLAMARREST INSULATED. FOIL SHIELDED. FOIL SIDE IN PLUS 24 AWG DRAIN. FLAMARREST JACKET BONDED TO SHIELD TAPE. SEQUENTAIL NUMBERING EVERY TWO FEET.
    1000 ea, WHITE
    • Mfr's Part No.: 6500PE 0091000
    • IWC Item No.: B-6500PE-9-1000
  81. Belden 6500PE 0101000 - 22 AWG - 2 C - 1000 EA - 300 V RMS - BLACK

    22 AWG 7X30 TINNED COPPER. 2 CONDUCTORS. FLAMARREST INSULATED. FOIL SHIELDED. FOIL SIDE IN PLUS 24 AWG DRAIN. FLAMARREST JACKET BONDED TO SHIELD TAPE. SEQUENTAIL NUMBERING EVERY TWO FEET.
    1000 ea, BLACK
    • Mfr's Part No.: 6500PE 0101000
    • IWC Item No.: B-6500PE-10-1000
  82. Belden 7929A 0102000 - 24 AWG - C - 2000 EA - 300 V RMS - BLACK

    Industrial Ethernet Cable. 4 Pair ScTP. 200MHz Category 5e. Riser Rated. #24 Solid Bare Copper. Polyolefin Insulation Singles Adjoined. Foil Shield Bonded to PVC Jacket. Sequential Marking at Two Foot Intervals
    2000 ea, BLACK
    • Mfr's Part No.: 7929A 0102000
    • IWC Item No.: B-7929A-10-2000
  83. Belden 7938A B59500 - 24 AWG - C - 500 FT - 300 V RMS - BLACK/MATTE

    500 ft, BLACK/MATTE
    • Mfr's Part No.: 7938A B59500
    • IWC Item No.: B-7938A-B59-500
  84. Belden 8307 0601000 - 22 AWG - C - 1000 EA - 300 V RMS (UL AWM Style 2464) - CHROME

    22 AWG (7x30) Tinned Copper. 7 Pairs. S-R PVC insulation. overall Polyester/Alum Tape Plus 65% Tinned Copper Braid Shield. PVC Jacket.
    1000 ea, CHROME
    • Mfr's Part No.: 8307 0601000
    • IWC Item No.: B-8307-1000
  85. Belden 83394 002500 - 22 AWG - 2 C - 500 FT - 2000 V DC^350 V RMS - RED

    22 AWG (7x30) tinned copper. FEP insulation. two conductors. conductive nylon plus Beldfoil shield with 22 AWG (7x30) tinned copper drain wire. silicone jacket.
    500 ft, RED
    • Mfr's Part No.: 83394 002500
    • IWC Item No.: B-83394-500
  86. Belden 8437 0101000 - 22 AWG - C - 1000 EA - 300 V RMS (UL AWM Style 2095) - BLACK

    22 AWG solid tinned copper. 1 pair. PVC insulated. overall polyester tape + 88% tinned copper braid shield with 22 awg solid tinned copper drain wire. PVC jacket.
    1000 ea, BLACK
    • Mfr's Part No.: 8437 0101000
    • IWC Item No.: B-8437-1000
  87. Belden 8728 0601000 - 22 AWG - C - 1000 EA - 300 V RMS (UL AWM Style 2717) - CHROME

    2 PAIRS INDIVIDUALLY SHIELDED 22 AWG (7X30) TINNED COPPER. POLYPROPYLENE INSULATED. CABLED ON COMMON AXIS. PVC JACKET
    1000 ea, CHROME
    • Mfr's Part No.: 8728 0601000
    • IWC Item No.: B-8728-1000
  88. Belden 8760MN - 18 AWG - 3 C - Unshielded - Gray

    ,
    • Mfr's Part No.: 8760MN
    • IWC Item No.: B-8760MN
  89. Belden 8761MN - 18 AWG - 3 C - Unshielded - Gray

    ,
    • Mfr's Part No.: 8761MN
    • IWC Item No.: B-8761MN
  90. Belden 8762MN - 18 AWG - 3 C - Unshielded - Gray

    ,
    • Mfr's Part No.: 8762MN
    • IWC Item No.: B-8762MN
  91. Belden 8770MN - 18 AWG - 3 C - Unshielded - Gray

    ,
    • Mfr's Part No.: 8770MN
    • IWC Item No.: B-8770MN
  92. Belden 8771MN - 18 AWG - 3 C - Unshielded - Gray

    ,
    • Mfr's Part No.: 8771MN
    • IWC Item No.: B-8771MN
  93. Belden 8772MN - 18 AWG - 3 C - Unshielded - Gray

    ,
    • Mfr's Part No.: 8772MN
    • IWC Item No.: B-8772MN
  94. Belden 87760 0021000 - 18 AWG - C - 1000 FT - 300 V RMS - RED

    18 AWG (19X30) TINNED COPPER. 2 CONDUCTORS. FEP INSULATED. ALUMINUM/MYLAR SHIELDED (FOIL OUT PLUS 20 AWG DRAIN). FLUOROCOPOLYMER JACKETED
    1000 ft, RED
    • Mfr's Part No.: 87760 0021000
    • IWC Item No.: B-87760-1000
  95. Belden 8786 060500 - 24^22 AWG - 4^2 C - 500 EA - 300 V RMS - CHROME

    24 & 22 AWG (7X32 & 7X30) TC. VINYL INSULATED 4 CONDRS.(24 AWG) WITH OVERALL FOIL TAPE SHIELD. 2 CONDUCTORS UNSHIELDED. OVERALL CHROME PVC JACKET
    500 ea, CHROME
    • Mfr's Part No.: 8786 060500
    • IWC Item No.: B-8786-500
  96. Belden 8786 060U500 - 24^22 AWG - 4^2 C - U500 EA - 300 V RMS - CHROME

    24 & 22 AWG (7X32 & 7X30) TC. VINYL INSULATED 4 CONDRS.(24 AWG) WITH OVERALL FOIL TAPE SHIELD. 2 CONDUCTORS UNSHIELDED. OVERALL CHROME PVC JACKET
    u500 ea, CHROME
    • Mfr's Part No.: 8786 060U500
    • IWC Item No.: B-8786-U500
  97. Belden 8787 060500 - 24^22 AWG - 8^2 C - 500 EA - 350 V RMS - CHROME

    24 & 22 AWG (7X32 & 7X30) TC. 8 24 AWG CONDRS POLYETHYLENE INSUL.. 2 22 AWG CONDRS.. PVC INSULATED TWO QUADS OF 24 AWG CONDRS.-EACH QUAD WITH FOIL TAPE SHIELD. OVERALL CHROME PVC JACKET
    500 ea, CHROME
    • Mfr's Part No.: 8787 060500
    • IWC Item No.: B-8787-500
  98. Belden 8787 060U500 - 24^22 AWG - 8^2 C - U500 EA - 350 V RMS - CHROME

    24 & 22 AWG (7X32 & 7X30) TC. 8 24 AWG CONDRS POLYETHYLENE INSUL.. 2 22 AWG CONDRS.. PVC INSULATED TWO QUADS OF 24 AWG CONDRS.-EACH QUAD WITH FOIL TAPE SHIELD. OVERALL CHROME PVC JACKET
    u500 ea, CHROME
    • Mfr's Part No.: 8787 060U500
    • IWC Item No.: B-8787-U500
  99. Belden 88107 008500 - 24 AWG - 1 C - 500 FT - 300 V RMS - GRAY

    24 AWG stranded (7x32) tinned copper. 7-1/2 pairs. Foam Fep Insulation. overall 100% Beldfoil shield + 24 AWG (7x32) tinned copper drain wire. fluorocopolymer Jacket.
    500 ft, GRAY
    • Mfr's Part No.: 88107 008500
    • IWC Item No.: B-88107-500
  100. Belden 8870MN - 18 AWG - 3 C - Unshielded - Gray

    ,
    • Mfr's Part No.: 8870MN
    • IWC Item No.: B-8870MN

Items 1 to 100 of 175 total