B-1211A-1000

Temperature Rating, Non-UL: 80ºC (UL AWM Style 2464)
Temperature Range, Operating: -20ºC To +80ºC
Capacitance: 26.000
Capacitance (Metric): 85.306
Current, Max. Recommended: 1.8 Amps per conductor at 25ºC
Voltage, Max. Operating: 300 V RMS (UL AWM Style 2464)
Velocity of Propagation: 60
SKU: B-1211A-1000
Manufacturer: Belden
AWM Specification: UL Style 2464 (300 V 80ºC)
RoHS: Yes
EU CE Mark: Yes
NEC/(UL) Specification: CL2X
Mfr. Part No: 1211A 0101000
Flame Test - UL Flame Test: UL1685 UL Loading. VW-1, UL1685 UL Loading, VW-1
Weight: 23.0000
Color: BLACK
Cable Type: Non-Paired
Conductor Size (AWG): 26
Conductor Material: TC - Tinned Copper
Number of Conductors: 4
Conductor Stranding: 7x34
Insulation Material: PVC - Polyvinyl Chloride
Insulation Wall Thickness: .015
Insulation Wall Thickness (Metric): 0.381
Overall Nominal Diameter: 0.195
Outer Jacket Wall Thickness: .036
Outer Jacket Material: PVC - Polyvinyl Chloride
Outer Shield Coverage: 100
Outer Shield Material: Aluminum Foil-Polyester Tape-Aluminum Foil
Outer Shield Type: Tape
Amount: 1000 ea
Overall Cabling - Overall Nominal Diameter (Metric): 4.953
Outer Jacket - Nom. Wall Thickness (Metric): 0.9144
Belden 1211A 0101000 - 26 AWG - 4 C - 1000 EA - 300 V RMS (UL AWM Style 2464) - BLACK (B-1211A-1000) DatasheetAdd to Compare

B-1211A-500

Temperature Rating, Non-UL: 80ºC (UL AWM Style 2464)
Temperature Range, Operating: -20ºC To +80ºC
Capacitance: 26.000
Capacitance (Metric): 85.306
Current, Max. Recommended: 1.8 Amps per conductor at 25ºC
Voltage, Max. Operating: 300 V RMS (UL AWM Style 2464)
Velocity of Propagation: 60
SKU: B-1211A-500
Manufacturer: Belden
AWM Specification: UL Style 2464 (300 V 80ºC)
RoHS: Yes
EU CE Mark: Yes
NEC/(UL) Specification: CL2X
Mfr. Part No: 1211A 010500
Flame Test - UL Flame Test: UL1685 UL Loading. VW-1, UL1685 UL Loading, VW-1
Weight: 12.0000
Color: BLACK
Cable Type: Non-Paired
Conductor Size (AWG): 26
Conductor Material: TC - Tinned Copper
Number of Conductors: 4
Conductor Stranding: 7x34
Insulation Material: PVC - Polyvinyl Chloride
Insulation Wall Thickness: .015
Insulation Wall Thickness (Metric): 0.381
Overall Nominal Diameter: 0.195
Outer Jacket Wall Thickness: .036
Outer Jacket Material: PVC - Polyvinyl Chloride
Outer Shield Coverage: 100
Outer Shield Material: Aluminum Foil-Polyester Tape-Aluminum Foil
Outer Shield Type: Tape
Amount: 500 ea
Overall Cabling - Overall Nominal Diameter (Metric): 4.953
Outer Jacket - Nom. Wall Thickness (Metric): 0.9144
Belden 1211A 010500 - 26 AWG - 4 C - 500 EA - 300 V RMS (UL AWM Style 2464) - BLACK (B-1211A-500) DatasheetAdd to Compare

B-1212A-1000

Temperature Rating, Non-UL: 80ºC (UL AWM Style 2464)
Temperature Range, Operating: -20ºC To +80ºC
Capacitance: 26.000
Capacitance (Metric): 85.306
Current, Max. Recommended: 1.2 Amps per conductor @ 25ºC (10ºC rise in temp)
Voltage, Max. Operating: 300 V RMS (UL AWM Style 2464)
Velocity of Propagation: 60
SKU: B-1212A-1000
Manufacturer: Belden
AWM Specification: UL Style 2464 (300 V 80ºC)
RoHS: Yes
EU CE Mark: Yes
NEC/(UL) Specification: CL2X
Mfr. Part No: 1212A 0101000
Flame Test - UL Flame Test: UL1685 UL Loading. VW-1, UL1685 UL Loading, VW-1
Weight: 30.0000
Color: BLACK
Cable Type: Non-Paired
Conductor Size (AWG): 26
Conductor Material: TC - Tinned Copper
Number of Conductors: 6
Conductor Stranding: 7x34
Insulation Material: PVC - Polyvinyl Chloride
Insulation Wall Thickness: .015
Insulation Wall Thickness (Metric): 0.381
Overall Nominal Diameter: 0.22
Outer Jacket Wall Thickness: .0365
Outer Jacket Material: PVC - Polyvinyl Chloride
Outer Shield Coverage: 100
Outer Shield Material: Aluminum Foil-Polyester Tape-Aluminum Foil
Outer Shield Type: Tape
Amount: 1000 ea
Overall Cabling - Overall Nominal Diameter (Metric): 5.588
Outer Jacket - Nom. Wall Thickness (Metric): 0.9271
Belden 1212A 0101000 - 26 AWG - 6 C - 1000 EA - 300 V RMS (UL AWM Style 2464) - BLACK (B-1212A-1000) DatasheetAdd to Compare

B-1212A-500

Temperature Rating, Non-UL: 80ºC (UL AWM Style 2464)
Temperature Range, Operating: -20ºC To +80ºC
Capacitance: 26.000
Capacitance (Metric): 85.306
Current, Max. Recommended: 1.2 Amps per conductor @ 25ºC (10ºC rise in temp)
Voltage, Max. Operating: 300 V RMS (UL AWM Style 2464)
Velocity of Propagation: 60
SKU: B-1212A-500
Manufacturer: Belden
AWM Specification: UL Style 2464 (300 V 80ºC)
RoHS: Yes
EU CE Mark: Yes
NEC/(UL) Specification: CL2X
Mfr. Part No: 1212A 010500
Flame Test - UL Flame Test: UL1685 UL Loading. VW-1, UL1685 UL Loading, VW-1
Weight: 14.5000
Color: BLACK
Cable Type: Non-Paired
Conductor Size (AWG): 26
Conductor Material: TC - Tinned Copper
Number of Conductors: 6
Conductor Stranding: 7x34
Insulation Material: PVC - Polyvinyl Chloride
Insulation Wall Thickness: .015
Insulation Wall Thickness (Metric): 0.381
Overall Nominal Diameter: 0.22
Outer Jacket Wall Thickness: .0365
Outer Jacket Material: PVC - Polyvinyl Chloride
Outer Shield Coverage: 100
Outer Shield Material: Aluminum Foil-Polyester Tape-Aluminum Foil
Outer Shield Type: Tape
Amount: 500 ea
Overall Cabling - Overall Nominal Diameter (Metric): 5.588
Outer Jacket - Nom. Wall Thickness (Metric): 0.9271
Belden 1212A 010500 - 26 AWG - 6 C - 500 EA - 300 V RMS (UL AWM Style 2464) - BLACK (B-1212A-500) DatasheetAdd to Compare

B-1213A-1000

Temperature Range, Operating: -20ºC To +90ºC
Temperature Rating, UL: 90ºC
Capacitance: 26.000
Capacitance (Metric): 85.306
Current, Max. Recommended: 1.2 Amps per conductor @ 25ºC (10ºC rise in temp)
Voltage, Max. Operating: 300 V RMS
Velocity of Propagation: 60
SKU: B-1213A-1000
Manufacturer: Belden
AWM Specification: UL Style 2464 (300 V 80ºC)
RoHS: Yes
EU CE Mark: Yes
NEC/(UL) Specification: CL2X
Mfr. Part No: 1213A 0101000
Flame Test - UL Flame Test: UL1685 UL Loading. VW-1, UL1685 UL Loading, VW-1
Weight: 24.0000
Color: BLACK
Cable Type: Non-Paired
Conductor Size (AWG): 26
Conductor Material: TC - Tinned Copper
Number of Conductors: 8
Conductor Stranding: 7x34
Insulation Material: PVC - Polyvinyl Chloride
Insulation Wall Thickness: .015
Insulation Wall Thickness (Metric): 0.381
Overall Nominal Diameter: 0.239
Outer Jacket Wall Thickness: .0385
Outer Jacket Material: PVC - Polyvinyl Chloride
Outer Shield Coverage: 100
Outer Shield Material: Aluminum Foil-Polyester Tape-Aluminum Foil
Outer Shield Type: Tape
Amount: 1000 ea
Overall Cabling - Overall Nominal Diameter (Metric): 6.0706
Outer Jacket - Nom. Wall Thickness (Metric): 0.9779
Belden 1213A 0101000 - 26 AWG - 8 C - 1000 EA - 300 V RMS - BLACK (B-1213A-1000) DatasheetAdd to Compare

B-1213A-500

Temperature Range, Operating: -20ºC To +90ºC
Temperature Rating, UL: 90ºC
Capacitance: 26.000
Capacitance (Metric): 85.306
Current, Max. Recommended: 1.2 Amps per conductor @ 25ºC (10ºC rise in temp)
Voltage, Max. Operating: 300 V RMS
Velocity of Propagation: 60
SKU: B-1213A-500
Manufacturer: Belden
AWM Specification: UL Style 2464 (300 V 80ºC)
RoHS: Yes
EU CE Mark: Yes
NEC/(UL) Specification: CL2X
Mfr. Part No: 1213A 010500
Flame Test - UL Flame Test: UL1685 UL Loading. VW-1, UL1685 UL Loading, VW-1
Weight: 12.0000
Color: BLACK
Cable Type: Non-Paired
Conductor Size (AWG): 26
Conductor Material: TC - Tinned Copper
Number of Conductors: 8
Conductor Stranding: 7x34
Insulation Material: PVC - Polyvinyl Chloride
Insulation Wall Thickness: .015
Insulation Wall Thickness (Metric): 0.381
Overall Nominal Diameter: 0.239
Outer Jacket Wall Thickness: .0385
Outer Jacket Material: PVC - Polyvinyl Chloride
Outer Shield Coverage: 100
Outer Shield Material: Aluminum Foil-Polyester Tape-Aluminum Foil
Outer Shield Type: Tape
Amount: 500 ea
Overall Cabling - Overall Nominal Diameter (Metric): 6.0706
Outer Jacket - Nom. Wall Thickness (Metric): 0.9779
Belden 1213A 010500 - 26 AWG - 8 C - 500 EA - 300 V RMS - BLACK (B-1213A-500) DatasheetAdd to Compare

B-1214A-1000

Temperature Rating, Non-UL: 80ºC (UL AWM Style 2464)
Temperature Range, Operating: -20ºC To +80ºC
Capacitance: 26.000
Capacitance (Metric): 85.306
Current, Max. Recommended: 0.8 Amps per conductor @ 25ºC
Voltage, Max. Operating: 300 V RMS (UL AWM Style 2464)
Velocity of Propagation: 60
SKU: B-1214A-1000
Manufacturer: Belden
AWM Specification: UL Style 2464 (300 V 80ºC)
RoHS: Yes
EU CE Mark: Yes
NEC/(UL) Specification: CL2X
Mfr. Part No: 1214A 0101000
Flame Test - UL Flame Test: UL1685 UL Loading. VW-1, UL1685 UL Loading, VW-1
Weight: 57.0000
Color: BLACK
Cable Type: Non-Paired
Conductor Size (AWG): 26
Conductor Material: TC - Tinned Copper
Number of Conductors: 16
Conductor Stranding: 7x34
Insulation Material: PVC - Polyvinyl Chloride
Insulation Wall Thickness: .015
Insulation Wall Thickness (Metric): 0.381
Overall Nominal Diameter: 0.301
Outer Jacket Wall Thickness: .035
Outer Jacket Material: PVC - Polyvinyl Chloride
Outer Shield Coverage: 100
Outer Shield Material: Aluminum Foil-Polyester Tape-Aluminum Foil
Outer Shield Type: Tape
Amount: 1000 ea
Overall Cabling - Overall Nominal Diameter (Metric): 7.6454
Outer Jacket - Nom. Wall Thickness (Metric): 0.889
Belden 1214A 0101000 - 26 AWG - 16 C - 1000 EA - 300 V RMS (UL AWM Style 2464) - BLACK (B-1214A-1000) DatasheetAdd to Compare

* Required Fields

$0.0000
 

Quick Overview

Data Cables for Molex SEMMCONN and AMP® SDL Connectors
SKUConductor Size (AWG)Number of ConductorsAmount
B-1214A-100026161000 ea
B-1213A-500268500 ea
B-1213A-10002681000 ea
B-1212A-500266500 ea
B-1212A-10002661000 ea
B-1211A-500264500 ea
B-1211A-10002641000 ea